Tìm kiếm theo danh mục sản phẩm

 

 
 

  • TOP
  • KAMLOK

KAMLOK

KAMLOK Selection Guide

KAMLOK Consists of Four Parts

Select a KAMLOK based on the adapter-to-coupler connection as well as the connections to Equipment A and Equipment B.

How to Select

To select the right KAMLOK, work through the connection type, material, and other requirements in the following order.

  1. STEP 01

    Select
    an adapter

  2. STEP 02

    Select
    a coupler

  3. STEP 03

    Select
    the size
    (nominal diameter)

  4. STEP 04

    Select
    the material

  5. STEP 05

    Select
    by pressure

  6. STEP 06

    Select
    a gasket

    * The selection may need to be changed depending on the fluid.

Download Catalogs

step 01

Select an adapter

Select an adapter to match the connection type on Equipment A.

Select the connection type for Equipment A.

Equipment A

Adapter

Male thread

Search Products

Select the connection type for Equipment A from the options on the left.

step 02

Select a coupler

Select a coupler to match the connection type on Equipment B.

Select the connection type for Equipment B.

Equipment B

Coupler

Male thread

Search Products

Select the connection type for Equipment B from the options on the right.

TWINLOK Coupler

Lower the arms until they click to lock the connection.
Preventing the arms from loosening and the coupling from disconnecting ensures safer, more reliable connection and disconnection.

TOYOCONNECTOR Coupler

Toward zero fluid leakage and hose disconnection problems.
The MS (Multiple-Seal) structure compresses and securely holds the hose over a wide area, helping prevent fluid leakage and hose disconnection. No retightening is required.

step 03

Select the size (nominal diameter)

Check the nominal diameter in the equipment or piping specifications, drawings, markings, or other relevant information.

in. 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 4 5 6
mm 15 20 25 32 40 50 65 80 100 125 150

step 04

Select the material

  • Aluminum alloy
  • Stainless steel
  • Resin (PP)
  • Bronze
Chemical Resistance Table (Select Material by Fluid)

* When the body material is resin (PP), the operating temperature range is 0–60°C. For all other body materials, the operating temperature range is determined by the temperature rating of the gasket used.

step 05

Select by pressure

The values below are reference operating pressure ranges at 23°C when using a Buna-N (NBR) gasket.

(Unit: MPa)

Material Size
1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6
AL - 0.1~1.8 - 0.1~1.1 - 0.1~0.9 - 0.1~0.7 - 0.1~0.5
SST - 0.1~1.8 - 0.1~1.6 - 0.1~1.4 - 0.1~1.1 - 0.1~0.5
PP(23℃) - 0.1~0.7 - 0.1~0.7 - 0.1~0.4
PP(60℃) - 0.1~0.25 - 0.1~0.25 - 0.1~0.10 - 0.1~0.05
BR - 0.1~1.8 - 0.1~1.1 - 0.1~0.9 - 0.1~0.7

step 06

Select a gasket

Standard Gasket

Buna-N (NBR)

The standard gasket is the Buna-N (NBR), with an operating temperature range of -10 to 100°C.
* Not compliant with Japan’s Food Sanitation Act.

Replacement Gasket List

Select a suitable replacement gasket if the required operating temperature is outside the -10 to 100°C range or if compliance with Japan’s Food Sanitation Act is required.

Model GK-NBR GK-CR GK-PTFE GK-TJ/F GK-FKM GK-Q GK-EPDM GK-WCR GK-FKM/S GK-TZ/Q GK-TZ/F
Product appearance
Material Buna-N (NBR) Neoprene (CR) Fluorine resin (PTFE)
(solid)
Fluorine resin (PTFE)
jacket (with fluororubber)
Fluororubber Silicone rubber Ethylene-propylene rubber (EPDM) White neoprene (CR) Super fluororubber Silicone rubber fully covered with fluorine resin (FEP) Fluororubber fully covered with fluorine resin (FEP)
Size 1/2”~6” 1/2”~6” 1/2”~6” *1 1/2”~4” 1/2”~3” 1/2”~6” 1/2”~3” 1/2”~2 1/2”,4” 1/2”~2” 1/2”~4” 1/2”~4”
Reference operating temperature range Upper limit 100℃ 80℃ 100℃ 180℃ 180℃ 150℃ 120℃ 80℃ 180℃ *2 120℃ 120℃
Lower limit ‐10℃ ‐30℃ ‐50℃ 0℃ 0℃ ‐50℃ ‐10℃ ‐10℃ 0℃ ‐50℃ 0℃
Compliance with Food Sanitation Act
Usable with steam 〇 *2

*1 When using a solid fluorine resin (PTFE) gasket, select a coupler, adapter, and gasket of the same size.
Example: Use a 1/2" solid fluorine resin (PTFE) gasket together with a 1/2" coupler and a 1/2" adapter.

*2 For couplers with a super fluororubber gasket used with saturated steam, the coupler should be used at an operating temperature of no more than 160°C and an operating pressure of no more than 0.6 MPa.

Page Top

Chúng tôi cung cấp nhiều dịch vụ hỗ trợ khác nhau, từ việc lựa chọn sản phẩm lý tưởng cho các điều kiện sử dụng cụ thể đến việc tải xuống các chứng chỉ liên quan đến luật pháp và quy định, cũng như tải xuống các tài liệu như catalog.

Bạn có thể tải xuống các tài liệu hữu ích cho các vấn đề như “rò rỉ và tuột ống”, “các biện pháp tiết kiệm năng lượng” và “khả năng bám mùi và màu”.

Chúng tôi sử dụng video để giới thiệu những lợi ích khi sử dụng sản phẩm và cách lắp sản phẩm, vốn là những nội dung có thể khó hiểu nếu chỉ sử dụng văn bản và hình ảnh minh họa.

Chúng tôi đã tổng hợp những câu hỏi thường gặp của khách hàng trong phần “Câu hỏi thường gặp”.

Để hỗ trợ bạn đưa ra lựa chọn, chúng tôi cung cấp các ví dụ phổ biến về cải tiến cho ống mềm và khớp nối thông qua các nghiên cứu tình huống điển hình trong ngành.